{"id":2265,"date":"2022-09-22T11:42:15","date_gmt":"2022-09-22T17:42:15","guid":{"rendered":"https:\/\/gssenergy.ca\/?page_id=2265"},"modified":"2023-01-31T10:20:36","modified_gmt":"2023-01-31T17:20:36","slug":"combined-heat-and-power-chp","status":"publish","type":"page","link":"https:\/\/gssenergy.ca\/?page_id=2265","title":{"rendered":"Combined Heat and Power (CHP)"},"content":{"rendered":"<div  style='padding-bottom:10px; color:#b02b2c;' class='av-special-heading av-special-heading-h2 custom-color-heading blockquote modern-quote modern-centered  avia-builder-el-0  el_before_av_textblock  avia-builder-el-first  '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >Combined Heat and Power (CHP)<\/h2><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#b02b2c'><\/div><\/div><\/div>\n<section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><h5>GSS engages with private owners and developers to design, build, and operate CHP energy assets on their site, creating prosumers that connect with an energy sharing community.\u00a0 A microgeneration energy retailer connects you with the local microgrid, so buying your electricity and natural gas while exporting your excess electricity, has never been easier.<\/h5>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>HOW IT WORKS<\/strong><\/p>\n<p>Most renewable energy technologies can be somewhat intermittent (wind, solar), so using natural gas is the most constant and most reliable form of renewable energy as allowed by the current microgeneration regulation. Converting natural gas to heat and electricity not only provides the baseload energy, but it is financially advantageous and it\u2019s good for the environment as well. The excess electricity that is not consumed is sold back to the grid.<\/p>\n<p><strong>HOW IT SAVES MONEY\u00a0 &#8211; THE LESS YOU USE THE MORE YOU SAVE<\/strong><\/p>\n<p>The Energy Center can follow your electrical demand or produce the same amount of energy every hour, so the less energy that your building uses, the more energy that can be sold back to the grid, further reducing your energy costs.\u00a0 Residential homeowners and developers can produce green electrical and thermal energy with expected monthly savings that can also provide a source of residual income.<\/p>\n<p><strong>ENERGY SECURITY<\/strong><\/p>\n<p>The GSS Energy Center will still deliver electricity, heating and cooling to your home even if the electrical grid goes down. Businesses and the average person now have the ability to self-supply their power on-site while still remaining grid connected as a back-up and to export their surplus. This can create a more resilient energy network that is less susceptible to catastrophic natural disaster events. Community microgrids and decentralized energy networks can provide the security of uninterrupted energy.<\/p>\n<\/div><\/section>\n<div  style='padding-bottom:10px; color:#b02b2c;' class='av-special-heading av-special-heading-h2 custom-color-heading blockquote modern-quote modern-centered  avia-builder-el-2  el_after_av_textblock  el_before_av_hr  '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >GSS MICROGEN TECHNOLOGIES<\/h2><div class ='av-subheading av-subheading_below av_custom_color ' style='font-size:15px;'><p>AVAILABLE FOR YOUR HOME OR BUSINESS<\/p>\n<\/div><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#b02b2c'><\/div><\/div><\/div>\n<div  style='height:50px' class='hr hr-invisible   avia-builder-el-3  el_after_av_heading  el_before_av_one_fourth '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div>\n<div class=\"flex_column av_one_fourth  flex_column_div av-zero-column-padding first  avia-builder-el-4  el_after_av_hr  el_before_av_three_fourth  \" style='border-radius:0px; '><div  class='avia-image-container  av-styling-    avia-builder-el-5  avia-builder-el-no-sibling  avia-align-center '  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding=\"async\" class='wp-image-2321 avia-img-lazy-loading-not-2321 avia_image' src=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/FINAL_1.5-kw-generator-1.png\" alt='' title='FINAL_1.5 kw generator' height=\"197\" width=\"180\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div>\n<div class=\"flex_column av_three_fourth  flex_column_div av-zero-column-padding   avia-builder-el-6  el_after_av_one_fourth  el_before_av_one_fourth  \" style='border-radius:0px; '><section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><h6><span style=\"color: #bd4242;\"><strong>1.5 kW CHP Cogeneration Unit\u00a0<\/strong><\/span><\/h6>\n<ul>\n<li>1.5 kw natural gas CHP is in a weatherproof canopy<\/li>\n<li>Can be installed inside or outside.<\/li>\n<li>Suitable for domestic hot water and hydronic applications.<\/li>\n<li>Super quiet 45 dB<\/li>\n<\/ul>\n<p><strong>Produces 13140 kW of electricity annually \u2013 worth approx.$3547. <\/strong><strong>(@ 0.27 \/kW*)<\/strong><\/p>\n<p><strong>Produces 118 Gj of Hot Water 70\u00b0C (160\u00b0F) annually &#8211; worth approx. $1,003. <\/strong><strong>(@ $8.50 Gj*)<\/strong><\/p>\n<\/div><\/section><\/div><div class=\"flex_column av_one_fourth  flex_column_div av-zero-column-padding first  avia-builder-el-8  el_after_av_three_fourth  el_before_av_three_fourth  column-top-margin\" style='border-radius:0px; '><div  class='avia-image-container  av-styling-    avia-builder-el-9  avia-builder-el-no-sibling  avia-align-center '  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding=\"async\" class='wp-image-2300 avia-img-lazy-loading-not-2300 avia_image' src=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/4.4-kW-CHP_Clean.png\" alt='' title='4.4 kW CHP_Clean' height=\"197\" width=\"180\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div><\/p>\n<div class=\"flex_column av_three_fourth  flex_column_div av-zero-column-padding   avia-builder-el-10  el_after_av_one_fourth  el_before_av_one_fourth  column-top-margin\" style='border-radius:0px; '><section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><h6><span style=\"color: #bd4242;\"><strong>4.4 kW CHP Cogeneration Unit\u00a0<\/strong><\/span><\/h6>\n<ul>\n<li>4.4 kw natural gas CHP is in a sound enclosure<\/li>\n<li>Installed in your garage or outside in weatherproof shed.<\/li>\n<li>Suitable for domestic hot water and hydronic applications.<\/li>\n<li>Super quiet 55 dB<\/li>\n<\/ul>\n<p><strong>Produces 35000 kW of electricity annually \u2013 worth approx.$9,450. <\/strong><strong>(@ 0.27 \/kW*)<\/strong><\/p>\n<p><strong>Produces 200 Gj of Hot Water 70\u00b0C (160\u00b0F) annually &#8211; worth approx. $1,700. <\/strong><strong>(@ $8.50 Gj*)<\/strong><\/p>\n<\/div><\/section><\/div><div class=\"flex_column av_one_fourth  flex_column_div av-zero-column-padding first  avia-builder-el-12  el_after_av_three_fourth  el_before_av_three_fourth  column-top-margin\" style='border-radius:0px; '><div  class='avia-image-container  av-styling-    avia-builder-el-13  avia-builder-el-no-sibling  avia-align-center '  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding=\"async\" class='wp-image-2323 avia-img-lazy-loading-not-2323 avia_image' src=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/10-kw-CHP-teal-300x252.png\" alt='' title='10 kw CHP teal' height=\"252\" width=\"300\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/10-kw-CHP-teal-300x252.png 300w, https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/10-kw-CHP-teal.png 498w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div><\/div><\/div><\/div><\/p>\n<div class=\"flex_column av_three_fourth  flex_column_div av-zero-column-padding   avia-builder-el-14  el_after_av_one_fourth  el_before_av_one_fourth  column-top-margin\" style='border-radius:0px; '><section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><h6><span style=\"color: #bd4242;\"><strong>10 kW CHP Cogeneration Unit\u00a0<\/strong><\/span><\/h6>\n<ul>\n<li>SmartPower 10kw natural gas CHP is in a sound enclosure (65 dB)<\/li>\n<li>Installed in your garage or outside in weatherproof shed.<\/li>\n<li>Suitable for domestic hot water and hydronic applications.<\/li>\n<li>Automatic oil change system (including oil draining and refilling).<\/li>\n<li>Auto lube-oil system (to maintain oil level)<\/li>\n<li>Catalytic converter.<\/li>\n<li>Remote monitoring and control.<\/li>\n<\/ul>\n<p><strong>Produces 87600 kW of electricity annually &#8211; $23,652. <\/strong><strong>(@ 0.27 \/kW*)<\/strong><\/p>\n<p><strong>Produces 660 Gj of Hot Water 80\u00b0C (180\u00b0F) annually &#8211; $5,610. <\/strong><strong>(@ $8.50 Gj*)<\/strong><\/p>\n<\/div><\/section><\/div><div class=\"flex_column av_one_fourth  flex_column_div av-zero-column-padding first  avia-builder-el-16  el_after_av_three_fourth  el_before_av_three_fourth  column-top-margin\" style='border-radius:0px; '><div  class='avia-image-container  av-styling-    avia-builder-el-17  avia-builder-el-no-sibling  avia-align-center '  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding=\"async\" class='wp-image-2314 avia-img-lazy-loading-not-2314 avia_image' src=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/FINAL_Water-to-Air-Heat-Exchanger.png\" alt='' title='FINAL_Water to Air Heat Exchanger' height=\"168\" width=\"180\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div><\/p>\n<div class=\"flex_column av_three_fourth  flex_column_div av-zero-column-padding   avia-builder-el-18  el_after_av_one_fourth  el_before_av_one_fourth  column-top-margin\" style='border-radius:0px; '><section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><h6><span style=\"color: #bd4242;\"><strong>F\/A Furnace &#8211; HWT Conversion Kit Unit\u00a0<\/strong><\/span><\/h6>\n<ul>\n<li>Water to Air Heat Exchanger<\/li>\n<li>Installed in your existing furnace<\/li>\n<li>60,000 \u2013 220,000 BTU\/ hr<\/li>\n<li>Rated 175 psig &amp; 175\u00b0C<\/li>\n<\/ul>\n<\/div><\/section><\/div><div class=\"flex_column av_one_fourth  flex_column_div av-zero-column-padding first  avia-builder-el-20  el_after_av_three_fourth  el_before_av_three_fourth  column-top-margin\" style='border-radius:0px; '><div  class='avia-image-container  av-styling-    avia-builder-el-21  avia-builder-el-no-sibling  avia-align-center '  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding=\"async\" class='wp-image-2317 avia-img-lazy-loading-not-2317 avia_image' src=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/FINAL_Brazed-Plate-Heat-Exchanger-2.png\" alt='' title='FINAL_Brazed Plate Heat Exchanger' height=\"197\" width=\"180\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div><\/p>\n<div class=\"flex_column av_three_fourth  flex_column_div av-zero-column-padding   avia-builder-el-22  el_after_av_one_fourth  el_before_av_textblock  column-top-margin\" style='border-radius:0px; '><section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><ul>\n<li>Brazed Plate Heat Exchanger<\/li>\n<li>110,000-280,000 BTU Capacity<\/li>\n<li>Copper\/SS316L Stainless Steel<\/li>\n<li>Single Phase Circulating Pump<\/li>\n<\/ul>\n<\/div><\/section><\/div>\n<section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><p><em><strong>*All prices are based on August Micro-Generator 2022 rates<\/strong><\/em><\/p>\n<\/div><\/section>\n<div  style='padding-bottom:10px; color:#b02b2c;' class='av-special-heading av-special-heading-h2 custom-color-heading blockquote modern-quote modern-centered  avia-builder-el-25  el_after_av_textblock  el_before_av_two_fifth  '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >Thermal Energy Exchange and Storage System<\/h2><div class ='av-subheading av-subheading_below av_custom_color ' style='font-size:15px;'><p>(Active Zone Geothermal \u2013 Price varies by CHP Size &#038; Demand)<\/p>\n<\/div><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#b02b2c'><\/div><\/div><\/div>\n<div class=\"flex_column av_two_fifth  flex_column_div av-zero-column-padding first  avia-builder-el-26  el_after_av_heading  el_before_av_three_fifth  \" style='border-radius:0px; '><div  class='av-hotspot-image-container   av-hotspot-numbered av-mobile-fallback-active  av-close-on-click-tooltip  avia-builder-el-27  avia-builder-el-no-sibling  av-non-fullwidth-hotspot-image'  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class='av-hotspot-container'><div class='av-hotspot-container-inner-cell'><div class='av-hotspot-container-inner-wrap'><div class='av-image-hotspot av-image-hotspot-1 av-close-on-click-tooltip' data-avia-tooltip-position='right' data-avia-tooltip-alignment='centered' data-avia-tooltip-class='av-tt-default-width av-tt-pos-right av-tt-align-centered  av-mobile-fallback-active  av-close-on-click-tooltip-single  main_color av-tt-hotspot' data-avia-tooltip='&lt;p&gt;Building&lt;\/p&gt;\n' style='top: 83.3%; left: 45.7%; '><div class='av-image-hotspot_inner' style=' '>1<\/div><div class='av-image-hotspot-pulse' ><\/div><\/div><div class='av-image-hotspot av-image-hotspot-2 av-close-on-click-tooltip' data-avia-tooltip-position='top' data-avia-tooltip-alignment='left' data-avia-tooltip-class='av-tt-default-width av-tt-pos-above av-tt-align-left  av-mobile-fallback-active  av-close-on-click-tooltip-single  main_color av-tt-hotspot' data-avia-tooltip='&lt;p&gt;THERMAL STORAGE WELLS&lt;\/p&gt;\n&lt;p&gt;These wells could each be 30 TO 200 FT. deep depending on the heating demand of the building.&lt;\/p&gt;\n' style='top: 13.3%; left: 24.1%; '><div class='av-image-hotspot_inner' style=' '>2<\/div><div class='av-image-hotspot-pulse' ><\/div><\/div><div class='av-image-hotspot av-image-hotspot-3 av-close-on-click-tooltip' data-avia-tooltip-position='top' data-avia-tooltip-alignment='left' data-avia-tooltip-class='av-tt-default-width av-tt-pos-above av-tt-align-left  av-mobile-fallback-active  av-close-on-click-tooltip-single  main_color av-tt-hotspot' data-avia-tooltip='&lt;p&gt;HEADER SYSTEM&lt;\/p&gt;\n&lt;p&gt;Connects the wells to the building in a multi-ring configuration. A minimum of a 10\u2019 diameter and up, depending on the size of the CHP.&lt;\/p&gt;\n' style='top: 60%; left: 47.8%; '><div class='av-image-hotspot_inner' style=' '>3<\/div><div class='av-image-hotspot-pulse' ><\/div><\/div><img decoding=\"async\" class='wp-image-2297 avia-img-lazy-loading-not-2297 avia_image' src=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-232x300.png\" alt='' title='ThermalStorage Diagram-01'  height=\"300\" width=\"232\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-232x300.png 232w, https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-796x1030.png 796w, https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-768x994.png 768w, https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-1187x1536.png 1187w, https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-1583x2048.png 1583w, https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-1159x1500.png 1159w, https:\/\/gssenergy.ca\/wp-content\/uploads\/2022\/09\/ThermalStorage-Diagram-01-1-545x705.png 545w\" sizes=\"(max-width: 232px) 100vw, 232px\" \/><\/div><\/div><\/div><div class='av-hotspot-fallback-tooltip av-image-hotspot-1 av-close-on-click-tooltip'><div class='av-hotspot-fallback-tooltip-count'>1<div class='avia-arrow'><\/div><\/div><div class='av-hotspot-fallback-tooltip-inner clearfix'><p>\nBuilding<\/p>\n<\/div><\/div><div class='av-hotspot-fallback-tooltip av-image-hotspot-2 av-close-on-click-tooltip'><div class='av-hotspot-fallback-tooltip-count'>2<div class='avia-arrow'><\/div><\/div><div class='av-hotspot-fallback-tooltip-inner clearfix'><p>\nTHERMAL STORAGE WELLS<\/p>\n<p>These wells could each be 30 TO 200 FT. deep depending on the heating demand of the building.<\/p>\n<\/div><\/div><div class='av-hotspot-fallback-tooltip av-image-hotspot-3 av-close-on-click-tooltip'><div class='av-hotspot-fallback-tooltip-count'>3<div class='avia-arrow'><\/div><\/div><div class='av-hotspot-fallback-tooltip-inner clearfix'><p>\nHEADER SYSTEM<\/p>\n<p>Connects the wells to the building in a multi-ring configuration. A minimum of a 10\u2019 diameter and up, depending on the size of the CHP.<\/p>\n<\/div><\/div><\/div><\/div>\n<div class=\"flex_column av_three_fifth  flex_column_div av-zero-column-padding   avia-builder-el-28  el_after_av_two_fifth  avia-builder-el-last  \" style='border-radius:0px; '><section class=\"av_textblock_section \"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock  '   itemprop=\"text\" ><p>The Active Zone Geothermal system is used to balance the heating and cooling loads seasonally.<\/p>\n<p>It absorbs all the waste heat from the CHP in summer and shoulder seasons, stores it and sends it back to the home in the winter when needed.\u00a0 The heat recovered is typically 10\u00b0C to 40\u00b0C and is used primarily for water source heat pumps.\u00a0 The TEES system can use the perimeter rings to store winter cold and is used in the summer for cooling.<\/p>\n<p>The AZG borefield uses a high-performance geothermal PE-RT thermally fused polyethylene pipe that operates at -30\u00b0C to 90\u00b0C.<\/p>\n<\/div><\/section><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2265","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/gssenergy.ca\/index.php?rest_route=\/wp\/v2\/pages\/2265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gssenergy.ca\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gssenergy.ca\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gssenergy.ca\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gssenergy.ca\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2265"}],"version-history":[{"count":20,"href":"https:\/\/gssenergy.ca\/index.php?rest_route=\/wp\/v2\/pages\/2265\/revisions"}],"predecessor-version":[{"id":2422,"href":"https:\/\/gssenergy.ca\/index.php?rest_route=\/wp\/v2\/pages\/2265\/revisions\/2422"}],"wp:attachment":[{"href":"https:\/\/gssenergy.ca\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}